  • MLC Convert v.1.2.1.1

    Internal release

    1. Corrected MLC orientation for Lantis RTP files
    2. Leaves # is now correct for IMRT files
    3. Support of Nemo wait dialog

  • Nemo X v.2.4.2.2

    Internal release

    1. Corrected MLC orientation for Lantis RTP files
    2. Disabling of “Use current” option for secondary replacement MLC types
    3. Disabling of Jaw edit for secondary replacement MLC types

  • Nemo X v.2.4.2.1

    Internal release

    1. Support of Lantis RTP files
    2. Improved sanity checks of MLC files
    3. Nemo Wait dialog at startup and during MLC loading and IMRT calculations
    4. Clone Patient Data menu command
    5. Dosimetry Report now can be split into more than 1 page

  • MLC Convert v.1.2.0.1

    Internal release

    1. Support of Lantis RTP files

  • RT Device Manager v.2.4.1.1

    Internal release

    1. Debugged display of wedge factors data
    2. Modified nxschema (v.1.4) to support free wedge orientations and cartesian display of jaw apertures
    3. Improved UI

  • Nemo X v.2.4.1.1

    Internal release

    1. Support for free wedge orientations
    2. Removed Asymm B panel
    3. Added display of Jaws print coordinates including cartesian display
    4. If offset support is not available the offset is now disabled and works ok
    5. Find a bug in equivalent squares table: this mostly influenced TBI calculations (very large fields)

  • Nemo X v.2.4.0.6

    Internal release

    1. Debugged TBI beam view and print
    2. MUQA for TBI beams

  • Nemo X v.2.4.0.5

    Internal release

    1. Debugged TPR calculation

  • Nemo X v.2.4.0.4

    Internal release

    1. Debugged TBI beam edit
    2. Preliminary implementation of IMRT MLC factor on CAX (to be debugged)

  • Nemo X v.2.4.0.3

    Internal release

    1. Improvements from MLC Convert
    2. Removed bug in MLC factor PDD calculation
    3. Calculation depths <= build-up are now forbidden
    4. Now recommended jaws works ok even for leaves closing at position != 0
    5. Copyright 2007

  • RT Device Manager v.2.4.0.3

    Internal release

    1. Improvements from MLC Convert

  • MLC Convert v.1.1.0.8

    Internal release

    1. Improved internal management of dynamic and static MLCs
    2. Speed-up rendering of dynamic MLC
    3. Debugged magnification factor
    4. Display of magnification factor for shape

  • MLC Convert v.1.1.0.7

    Internal release

    1. Improved GUI for dynamic MLC files

  • Nemo X v.2.4.0.2

    Internal release

    1. First implementation of fluence map load and BEV rendering

  • RT Device Manager v.2.4.0.2

    Internal release

    1. Debugged save for new attenuation data

  • MLC Convert v.1.1.0.6

    Internal release

    1. First implementation of fluence map rendering (grey shades)

  • MLC Convert v.1.1.0.5

    Internal release

    1. Copyright 2007
    2. Now magnification factor is correctly read and rasterized
    3. Recommended Jaws for dynamic mlc

  • MLC Convert v.1.1.0.4

    Internal release

    1. MLC Convert is now part of the Nemo X project

  • RT Device Manager v.2.4.0.1

    Internal release

    1. Modified nxschema (v.1.3) to support attenuation and penumbra information for MLC and Jaws

  • Nemo X v.2.4.0.1

    Internal release

    1. Improved CoM localization for MLC shaped beams (now accounts also for jaws position)

  • RT Device Manager v.2.3.0.4

    Internal release

    1. Removed legacy code

  • Nemo X v.2.3.2.3

    Internal release

    1. Minor improvements in Details print form and photon beam Tree
    2. Removed legacy code
    3. Minor changes in TPSMUReport
    4. Debugged Scatter size for TBI beams

  • Nemo X v.2.3.2.2

    Internal release

    1. Scatter integration routine for asymmetric open beams

  • Nemo X v.2.3.1.1

    Internal release

    1. TPS MU Report file (photon beams)
    2. Minor changes in dosimetric details print form

  • Nemo X v.2.3.0.4

    Internal release

    1. New wedge depth dose routines
    2. Debugged treeview display for wedge data
    3. Now oppose & flip works ok even for mlc and wedged beams
    4. Removed calculation of temporary MLC factor (no more useless message window)
    5. MLC factor now accounts for jaws position in scatter integration routine
    6. New popup menus for depth and recommended jaws
    7. Removed print of wedge orientation in Dosimetric Details if PrintWedge is not selected

  • RT Device Manager v.2.3.0.3

    Internal release

    1. New nxschema with PDD data written as a pattern XML list (much smaller file dimension and faster loading)

  • Nemo X v.2.3.0.3

    Internal release

    1. Bug fix: PDD normdepth now correctly set to Calibration Depth (build-up in previous versions)
    2. Revised PDD routine for wedged beams

  • Nemo X v.2.2.1.3

    Internal release

    1. Some minor bug fixes

  • RT Device Manager v.2.3.0.1

    Internal release

    1. New nxschema including wedge PDD data
    2. New interface for wedge PDD data
    3. Some bug fix

  • Nemo X v.2.2.1.2

    Internal release

    1. Complete (initial) implementation of BEV rendering (new photon beam UI)
    2. Different usage of offset correction (new photon beam UI)
    3. Some (internal) bug fix
    4. New Dose Rate indication on photon beam tree view

  • Nemo X v.2.2.0.2

    Internal release

    1. New MLC factor calculation with Clarkson integration and Scatter Model Function
    2. Some bug removed
    3. Now MUQA can proceed also for > 10% difference (IMRT) but requires double confirmation
    4. Initial implementation of BEV rendering on Photon Beam window

  • Nemo X v.2.2.0.1

    Internal release

    1. Equivalent size for rectangular fields computed using Venselaar table